MSC Remote Control
CueCollab can receive MIDI Show Control (MSC) Go commands and use them to update the current environment scene name — the same scene name that appears in notes, displays, and recordings.
How It Works
Section titled “How It Works”When a Go command is received, CueCollab extracts the cue list and cue number from the message and sets the scene name to <cue-list>.<cue> (e.g. 1.5). Filter options let you restrict which device IDs, command formats, and cue lists trigger updates.
CueCollab Setup
Section titled “CueCollab Setup”Go to Admin → Remote Control and configure the following sections:
MIDI Show Control (MSC)
Section titled “MIDI Show Control (MSC)”| Setting | Description |
|---|---|
| Enable MSC | Enables the MSC listener. Go commands received on the configured port update the environment scene name. |
| Device | The MSC device or group ID CueCollab responds to. Options: All devices (0x7F), Groups G1–G15, or individual device IDs 1–111. Match this to your sending device. |
| Command Format | The MSC command format to accept: All (0x7F), Lighting General, Sound General, Machinery General, Video General, Projection General, Process Control General, or Pyro General. Match this to your sending device. |
| Allowed Cue Lists | Optionally restrict which cue list numbers trigger updates. Leave empty to accept Go commands from all cue lists. |
MSC GrandMA2 Ethernet Integration
Section titled “MSC GrandMA2 Ethernet Integration”| Setting | Description |
|---|---|
| Enable grandMA2 Ethernet | Enables receiving MSC from a grandMA2 Ethernet output. Required for grandMA2 MSC to function. |
| MSC Port | The UDP port CueCollab listens on for grandMA2 MSC messages. Valid range: 6000–6100. |
Click Save to apply all Remote Control settings.
grandMA2 Setup
Section titled “grandMA2 Setup”-
Make sure your grandMA2 console is on the same network as the CueCollab server and can reach it on the configured MSC port.
-
In grandMA2, go to Setup > Console > MIDI Show Control and configure:
Setting Value MSC Out Mode Ethernet Ethernet Port MSC port configured in CueCollab (default: 6004) MSC Out Device Device/group ID matching the Device setting in CueCollab MSC Out Command Command format matching the Command Format in CueCollab MSC Out Exec Exec.Page
More information on grandMA2 MSC output can be found in the grandMA2 manual — MIDI Show Control section.
Related
Section titled “Related”- Admin → Remote Control — enable and configure MSC in CueCollab
- Admin → Environment — view and manually override the current scene name
- OSC GrandMA Integration — alternative integration using the Lua plugin (sends cue name instead of cue number)